98 Powermax125 Service Manual 808070
6 Machine Torch Setup
FineCut – stainless steel
Air flow rate slpm/scfh
Hot 217 / 460
Cold 226 / 480
Metric
Material
Thickness
Current
Torch-to-Work
Distance
Initial Pierce Height
Pierce Delay
Time
Recommended
Cut Speed Voltage
mm A mm mm % seconds mm/min volts
0.5
30
0.02 0.08 400
0.0
4825 77
0.6 4825 77
0.8 0.1 4825 73
1
40
0.2 4825 86
1.5
0.4
4825 72
2
45
4550 72
3
0.5
2335 70
4 995 72
English
Material
Thickness
Current
Torch-to-Work
Distance
Initial Pierce Height
Pierce Delay
Time
Recommended
Cut Speed Voltage
inches A inches inches % seconds ipm volts
26 GA
30
0.02 0.08 400
0.0
190 77
24 GA 190 77
22 GA
0.1
190 74
20 GA 190 72
18 GA
40
0.2 190 80
16 GA
0.4
190 72
14 GA
45
190 72
12 GA
0.5
110 70
10 GA 70 71

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand