65 A shielded cutting – mild steel
Air flow rate slpm/scfh
Hot 222 / 470
Cold 250 / 530
Metric
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
mm mm mm % seconds mm/min volts mm/min volts
2
1.5
3.8 250
0.1 5930 122 7015 123
3 0.2 5150 123 6080 123
4
0.5
4370 123 5145 123
6 2815 125 3275 124
8 2080 127 2235 126
10
4.5 300
0.7 1520 129 1490 128
12 1.2 960 131 1140 130
16 6 400 2.0 656 136 740 135
20
Edge start
355 141 450 140
25 215 146 270 146
English
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
inches inches inches % seconds ipm volts ipm volts
16 GA
0.06
0.15 250
0.1
248 122 294 122
10 GA 190 123 224 123
3/16 0.2 149 124 174 123
1/4 0.5 100 125 116 124
3/8 0.7 65 129 62 128
1/2 0.18 300 1.2 30 132 40 131
5/8 0.24 400 2.0 23 136 30 135
3/4
Edge Start
15 140 19 139
7/8 12 143 15 143
1814610146

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax 125
CategoryWelding System
LanguageEnglish

Related product manuals