94 Powermax125 Service Manual 808070
6 Machine Torch Setup
45 A shielded cutting – stainless steel
Air flow rate slpm/scfh
Hot 217 / 460
Cold 241 / 510
Metric
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
mm mm mm % seconds mm/min volts mm/min volts
0.5
0.5 2.0 400
0.0
8890 113 12510 120
1 8890 113 10760 120
1.5 0.1 7825 117 10160 120
2
1.5 3.8 250
0.3 6095 122 8615 122
3
0.4
3585 123 4405 123
4 2185 126 2565 126
6 0.5 975 132 1020 132
English
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
inches inches inches % seconds ipm volts ipm volts
26 GA
0.02 0.08 400
0.0
350 113 500 120
22 GA 350 113 450 120
18 GA
0.1
350 113 400 120
16 GA 305 117 400 120
14 GA
0.06 0.15 250
0.2 250 122 360 122
12 GA
0.4
175 123 206 123
10 GA 100 124 134 124
3/16 0.5 68 128 58 128
1/4 0.6 30 133 35 133

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand