164 Powermax125 Service Manual 808070
8 Troubleshooting and System Tests
Test 11 Fan
Symptom: The fan does not operate properly.
Wear proper personal protective equipment (PPE) before testing powered equipment.
1. Remove the inverter temperature sensor plug from J2 on the power board.
2. Place a jumper between pin 1 and pin 3 of connector J2 on the power board.
3. Remove the white cover from the fan control cable at J1.
4. Turn the machine ON. (The fan should be running.)
5. With the fan control cable connected to J1, measure the DC voltage between pin 1 and pin 4 in the plug.
a. If the voltage is 48 VDC (±5%), replace the fan.
b. If the voltage is not correct:
Remove the fan control cable and re-measure the DC voltage on the power board connector
between pin 1 and pin 4 of J1.
If the voltage is 48 VDC, replace the fan. Otherwise, perform Test 5 Flyback circuit (DC minor
voltages) on page 156.
c. If the system passes the flyback circuit test:
If the voltage between pin 1 and pin 3 (J1) is 0 VDC, replace the DSP board.
If the voltage is greater than 0 VDC, replace the power board.
Test 12 AUX switch
Symptom: Upon power-up, fault code 0-19 displays. After 1 minute, fault code 0-99 displays. In service mode, the live
fault code is 2-01-1.
1. Turn the machine OFF and disconnect the power.
2. Disconnect the auxiliary switch cable from J5 on the power board.
3. Measure the resistance on the cable plug between pin 4 and pin 5.
4. If the power switch is closed (ON) there should be very low resistance.
5. If the power switch is open (OFF) there should be very high resistance.
6. If the resistance measurement does not agree, check the cable, plug, and switch for opens or shorts.

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand

Related product manuals