236 Powermax125 Service Manual 808070
9 Power Supply Component Replacement
Replacing the work lead receptacle
1. Complete the following procedures:
a. See Disconnect the power and gas supply on page 166.
b. See Remove the power supply cover on page 172.
c. See Remove the fan shroud on page 216.
2. Remove the bolt securing the work cable to the work lead receptacle.
3. Remove the nut and lock washer securing the work lead receptacle to the front panel.
4. Push the work lead receptacle out through the front panel.
Figure 93
Kit number Description
228912 Kit: Powermax105/125 work lead receptacle (power supply side)
1
2
3
4
5
1 Work lead receptacle
2 Bolt
3 Work cable
4 Nut
5 Lock washer

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand