6 Machine Torch Setup
65 A shielded cutting – aluminum
Air flow rate slpm/scfh
Hot 222 / 470
Cold 250 / 530
Metric
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
mm mm mm % seconds mm/min volts mm/min volts
2
1.5
3.8 250
0.1 7805 123 10265 122
3 0.2 6565 125 8790 123
4
0.5
5320 126 7320 124
6 2845 129 4375 126
8
0.7
2015 133 2750 129
10
4.5 300
1535 136 1650 132
12 1.2 1055 139 1330 135
16
Edge Start
640 143 805 140
20 335 146 550 144
English
Material
Thickness
Torch-to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
inches inches inches % seconds ipm volts ipm volts
1/16
0.06
0.15 250
0.1
328 123 428 122
1/8 250 125 336 123
1/4 0.5 95 130 152 126
3/8 0.7 65 135 68 131
1/2 0.18 300 1.2 35 140 48 136
5/8
Edge Start
26 143 32 140
3/4 16 145 24 143

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand