10 Torch Component Replacement
Replacing the torch lead
1. Complete the following procedures:
a. See Disconnect the power, gas supply, and torch on page 266.
b. Remove all components from the torch. See Remove the handle on page 269.
2. Disconnect the cap-sensor switch and start switch.
Figure 138
3. Remove the pilot terminal screw.
Figure 139
Kit Description
428159 Kit: Duramax Hyamp hand torch lead replacement, 7.6 m (25 foot)
428160 Kit: Duramax Hyamp hand torch lead replacement, 15 m (50 foot)
428161 Kit: Duramax Hyamp hand torch lead replacement, 23 m (75 foot)
Cap-sensor switch
Tab
Tab
Start switch

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand