282 Powermax125 Service Manual 808070
10 Torch Component Replacement
4. Use a 3/8-inch and 1/2-inch wrench together (or 2 adjustable wrenches) to loosen the gas fitting that secures the
torch body to the torch lead.
5. Apply threadlocker (330103) to the threads of the gas tube fitting on the torch body. Be very careful not to get any
threadlocker on the conical surface of the gas tube fitting to avoid damage to the torch. (See Figure 140.)
Figure 140
CAUTION!
Always use 2 wrenches to properly loosen and tighten the hex nuts and bolts mentioned in these
procedures.
CAUTION!
Do not get any threadlocker on the conical surface of the gas tube fitting to avoid causing damage
to the torch. If any threadlocker does get on this surface, clean it off immediately.
Conical surface of the gas tube
fitting

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand