Operation
Powermax45 XP Operator Manual 809240 55
2. Press-and-hold the Mode 
button with one hand. Turn 
the adjustment knob to the 
desired gas pressure with the 
other hand. In this example, 
we turned down the gas 
pressure to 35 psi.
 As you manually 
adjust the gas 
pressure, the AMPS 
LED turns off, and the 
2-digit display 
changes from 
amperage to gas 
pressure, as follows:
 CSA models: The gas pressure displays in psi by default.
 CE/CCC models: The gas pressure displays in bar by default.
You can change the display values for gas pressure. See page 57.
3. Release the Mode button.
 After you release the 
Mode button, the 
AMPS LED 
illuminates again, and 
the 2-digit display 
changes from gas 
pressure back to 
amperage.
 The selected mode LED blinks to let you know that the gas pressure has been manually 
adjusted. It continues to blink until you reset the pressure.
 To view the gas pressure setting again, repeat step 2 above, or enter gas test mode. 
See Run a gas test on page 149.
Press-and-hold the button while turning the knob.