EasyManuals Logo

IBM V7000 User Manual

IBM V7000
670 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #110 background imageLoading...
Page #110 background image
90 IBM Flex System V7000 Storage Node Introduction and Implementation Guide
3.2 IBM Flex System Chassis Management Module (CMM)
The IBM Flex System Chassis Management Module (CMM) is a hot-swap module that
configures and manages all installed chassis components. The chassis comes with one IBM
Flex System Chassis Management Module in the CMM bays.
The IBM Flex System Chassis Management Module auto-detects and manages the hardware
of the entire IBM Flex System Enterprise Chassis. It communicates with the management
controller in each node (IMMv2 in intel processor-based computer nodes, FSP in power
Power7 processor-based nodes), along with the management applications of storage node
and I/O modules to provide centralized system monitoring and management.
3.2.1 Overview of IBM Flex System Chassis Management Module
The IBM Flex System Chassis Management Module (CMM) gives control over the IBM Flex
System at the chassis level, simplifying installation and management of your installation.
The CMM is central to the management of the chassis, and is required in the IBM Flex
System Enterprise Chassis. One CMM comes standard with the chassis. There are two CMM
bays in the chassis, giving the user an option to add a second CMM for redundancy.
Through an embedded firmware stack, the CMM implements functions to monitor, control,
and provide external user interfaces to manage all chassis resources. Here are the key
functions of the IBM Flex System Chassis Management Module:
򐂰 Single-chassis management
򐂰 Initial setup configuration wizard from http/s interface
򐂰 Detailed system health status for components, along with suggested recovery actions
򐂰 Chassis level hardware inventory management
򐂰 Chassis configuration and validation
򐂰 System and component status information
򐂰 Component LEDs states and controls
򐂰 Event handling and notification
򐂰 Hardware access states
򐂰 Fan status and control
򐂰 Thermal management and monitoring
򐂰 Power management and control
򐂰 Switch modules - monitor and control access
򐂰 Security features and policies
򐂰 Service data collection and Call Home services
򐂰 Configuration backup and restore
򐂰 Firmware updates
򐂰 Low level service processor resets
򐂰 Nodes and I/O module configuration and management
򐂰 Diagnostics
򐂰 Network management
򐂰 Chassis and compute node initialization
Tip: The IBM Flex System Enterprise Chassis supports up to 84 local CMM user accounts,
and allows up to 32 simultaneous sessions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM V7000 and is the answer not in the manual?

IBM V7000 Specifications

General IconGeneral
ModelIBM Storwize V7000
Storage TypeHybrid Flash Array
Maximum Capacity1.2PB
RAID Levels0, 1, 5, 6, 10
Connectivity8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI
ManagementCommand-line interface (CLI), Graphical user interface (GUI)
Form Factor2U
Drive Bays12
Maximum Raw Capacity1.2PB
Operating System SupportAIX, HP-UX, Linux, VMware, Windows
Data Reduction FeaturesReal-time Compression, Deduplication
Drive TypesSSD, HDD
ScalabilityScale-up (drive enclosures) and scale-out (clustering) capabilities

Related product manuals