572 IBM Flex System V7000 Storage Node Introduction and Implementation Guide
13.1 Reliability, availability, and serviceability (RAS)
Reliability, availability, and serviceability (RAS) are important concepts in the design of the
IBM Flex System V7000 Storage Node. Hardware features, software features, design
considerations, and operational guidelines all contribute to make IBM Flex System V7000
Storage Node reliable.
Fault tolerance and high levels of availability are achieved as follows:
򐂰 RAID capabilities of the underlying disk subsystems
򐂰 IBM Flex System Flex System V7000 nodes clustering using a
Compass architecture
򐂰 Auto-restart of hung nodes
򐂰 Battery units to provide memory protection in the event of a site power failure
򐂰 Host system failover capabilities
High levels of serviceability are achieved by providing the following capabilities:
򐂰 Cluster error logging
򐂰 Asynchronous error notification
򐂰 Dump capabilities to capture software detected failures
򐂰 Concurrent diagnostic procedures
򐂰 Directed maintenance procedures
򐂰 Concurrent log analysis and memory dump data recovery tools
򐂰 Concurrent maintenance of all IBM Flex System V7000 components
򐂰 Concurrent upgrade of IBM Flex System V7000 Software and microcode
򐂰 Concurrent addition or deletion of the IBM Flex System V7000 nodes canister in a cluster
򐂰 Software recovery through a service panel push button
򐂰 Automatic software version correction when replacing a node
򐂰 Detailed status and error conditions displayed on the service panel
򐂰 Error and event notification through SNMP, syslog, and email
At the heart of IBM Flex System V7000 Storage Node is a pair of node canisters. These two
canisters share the data transmitting and receiving load between the attached hosts and the
disk arrays. This section looks at the RAS features of the IBM Flex System V7000 Storage
Node system monitoring and troubleshooting.
We highly recommend that you review and be familiar with “IBM Flex System V7000 Storage
Node Configuration Limits and Restrictions,” at the following website:
http://www.ibm.com/support/docview.wss?uid=ssg1S1004369
Also, for the interoperability matrix, see the System Storage Interoperability Center (SSIC),
at the following website:
http://www.ibm.com/systems/support/storage/ssic/interoperability.wss
Before installing IBM Flex System V7000 Storage Node, make sure that you review the
content of this document: “Limitations with the Management of Flex System V7000 Storage
Node, Storwize V7000, and SAN Volume Controller Storage by IBM Flex System Manager,
at the following website:
http://publib.boulder.ibm.com/infocenter/flexsys/information/topic/com.ibm.acc.com
montasks.doc/flex_storage_management.pdf

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM V7000 and is the answer not in the manual?

IBM V7000 Specifications

General IconGeneral
BrandIBM
ModelV7000
CategoryStorage
LanguageEnglish

Related product manuals