602 IBM Flex System V7000 Storage Node Introduction and Implementation Guide
13.7.2 Upgrade procedure
The following procedure upgrades drive firmware on a drive that is in the control enclosure or
expansion enclosures. If the upgrade would cause any volumes to go offline, the force option
is required.
To upgrade drive firmware, follow this procedure:
1. Run the following command for the drive that you are upgrading:
If any volumes are returned, continuing with this procedure takes the volumes offline. To
avoid losing access to data, resolve any redundancy errors to remove this problem before
you continue with the upgrade procedure.
2. Locate the firmware upgrade downloads at the following IBM website:
http://www.ibm.com/support/entry/portal/downloads/hardware/puresystems/pureflex
_system/storage_node/flex_system_v7000
This website also provides a link to the Software Upgrade Test Utility. This utility indicates
if any of your drives are not running at the latest level of firmware.
3. Using scp or pscp, copy the firmware upgrade file and the Software Upgrade Test Utility
package to the /home/admin/upgrade directory by using the management IP address.
4. Run the applydrivesoftware command. You must specify the firmware upgrade file, the
firmware type, and the drive ID.
To apply the upgrade even if it causes one or more volumes to go offline, specify the
-force option.
13.8 Troubleshooting
This section describes IBM Flex System V7000 Storage Node error events reporting and
notification, and can help in understanding the error codes.
For more details on using FSM for troubleshooting tasks, see the following website:
http://publib.boulder.ibm.com/infocenter/flexsys/information/index.jsp?topic=%2Fco
m.ibm.acc.4939.doc%2Fsite_qicfgsys_FSM.html
Command: lsdependentvdisks -drive drive_id
Command: applydrivesoftware -file filename -type firmware -drive drive_id
Attention: Do not use the -type fpga option, which upgrades Field Programmable
Gate Array (FPGA) firmware, unless directed to do so by an IBM service representative.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM V7000 and is the answer not in the manual?

IBM V7000 Specifications

General IconGeneral
ModelIBM Storwize V7000
Storage TypeHybrid Flash Array
Maximum Capacity1.2PB
RAID Levels0, 1, 5, 6, 10
Connectivity8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI
ManagementCommand-line interface (CLI), Graphical user interface (GUI)
Form Factor2U
Drive Bays12
Maximum Raw Capacity1.2PB
Operating System SupportAIX, HP-UX, Linux, VMware, Windows
Data Reduction FeaturesReal-time Compression, Deduplication
Drive TypesSSD, HDD
ScalabilityScale-up (drive enclosures) and scale-out (clustering) capabilities