EasyManuals Logo

IBM V7000 User Manual

IBM V7000
670 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #206 background imageLoading...
Page #206 background image
186 IBM Flex System V7000 Storage Node Introduction and Implementation Guide
Figure 4-38 Change Service IP by CMM procedure
Changing the Service IP address by CLI
These addresses are not set during the installation of a Flex System V7000 Storage Node
system, but you can set these IP addresses later by using the chserviceip CLI command.
4.6 Command-Line interface (CLI)
The Flex System V7000 Storage Node command-line interface (CLI) is a collection of
commands that you can use to manage a Flex System V7000 Storage Node.
You can use the CLI to perform the following functions:
򐂰 Setup of the clustered system, its nodes, and the I/O groups
򐂰 Analyzing error logs (event logs)
򐂰 Setup and maintenance of managed disks (MDisk) and storage pools
򐂰 Setup and maintenance of client public SSH keys on the clustered system
򐂰 Setup and maintenance of volumes
򐂰 Setup of logical host objects
򐂰 Mapping volumes to hosts
򐂰 Navigating from managed hosts to volumes and MDisks, and reverse direction up chain.
򐂰 Setting up and starting Copy Services:
FlashCopy and FlashCopy consistency groups
Synchronous Metro Mirror and Metro Mirror consistency groups
Asynchronous Global Mirror and Global Mirror consistency groups
The CLI commands use the Secure Shell (SSH) connection between the SSH client software
on the host system and the SSH server on the Flex System V7000 Storage Node. Install and
set up SSH client software on each system that you plan to use to access the CLI.
Authenticate to the system using a password. If you require command line access without
entering a password, use an SSH public key. Then store the SSH public key for each SSH
client on the Flex System V7000 Storage Node.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM V7000 and is the answer not in the manual?

IBM V7000 Specifications

General IconGeneral
ModelIBM Storwize V7000
Storage TypeHybrid Flash Array
Maximum Capacity1.2PB
RAID Levels0, 1, 5, 6, 10
Connectivity8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI
ManagementCommand-line interface (CLI), Graphical user interface (GUI)
Form Factor2U
Drive Bays12
Maximum Raw Capacity1.2PB
Operating System SupportAIX, HP-UX, Linux, VMware, Windows
Data Reduction FeaturesReal-time Compression, Deduplication
Drive TypesSSD, HDD
ScalabilityScale-up (drive enclosures) and scale-out (clustering) capabilities