EasyManuals Logo

IBM V7000 User Manual

IBM V7000
670 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #587 background imageLoading...
Page #587 background image
Chapter 12. Host configuration 567
Hosts that use 2.6 kernel Linux operating systems can have as many FC disks as the SVC
allows. The following website provides the most current information about the maximum
configuration for the SVC:
http://www.ibm.com/storage/support/2145
12.6.5 Creating and preparing DM-MPIO volumes for use
First, you have to start the MPIO daemon on your system. Run either the following SLES10
command or the following RHEL5 command on your host system:
򐂰 Enable MPIO for SLES10 by running the following commands:
/etc/init.d/boot.multipath {start|stop}
/etc/init.d/multipathd
{start|stop|status|try-restart|restart|force-reload|reload|probe}
򐂰 Enable MPIO for RHEL5 by running the following commands:
modprobe dm-multipath
modprobe dm-round-robin
service multipathd start
chkconfig multipathd on
Example 12-28 shows the commands that are issued on a Red Hat Enterprise Linux 5.1
operating system.
Example 12-28 Starting MPIO daemon on Red Hat Enterprise Linux
[root@palau ~]# modprobe dm-round-robin
[root@palau ~]# multipathd start
[root@palau ~]# chkconfig multipathd on
[root@palau ~]#
Follow these steps to enable multipathing for IBM devices:
1. Open the multipath.conf file and follow the instructions. The file is located in the /etc
directory. Example 12-29 shows editing using vi.
Example 12-29 Editing the multipath.conf file
[root@palau etc]# vi multipath.conf
2. Add the following entry to the multipath.conf file:
device {
vendor "IBM"
product "2145"
path_grouping_policy group_by_prio
prio_callout "/sbin/mpath_prio_alua /dev/%n"
}
Tip: Run insserv boot.multipath multipathd to automatically load the multipath
driver and multipathd daemon during start-up.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM V7000 and is the answer not in the manual?

IBM V7000 Specifications

General IconGeneral
ModelIBM Storwize V7000
Storage TypeHybrid Flash Array
Maximum Capacity1.2PB
RAID Levels0, 1, 5, 6, 10
Connectivity8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI
ManagementCommand-line interface (CLI), Graphical user interface (GUI)
Form Factor2U
Drive Bays12
Maximum Raw Capacity1.2PB
Operating System SupportAIX, HP-UX, Linux, VMware, Windows
Data Reduction FeaturesReal-time Compression, Deduplication
Drive TypesSSD, HDD
ScalabilityScale-up (drive enclosures) and scale-out (clustering) capabilities