Appendix A. CLI setup and configuration 639
8. Highlight the new session and click Open to connect to the IBM Flex System V7000
Storage Node. A PuTTY Security Alert opens; confirm it by clicking Yes (Figure A-15).
Figure A-15 Confirm Security Alert
9. PuTTY now connects to the system and prompts you for a user name. Enter admin as the
user name and press Enter (Example A-1).
Example: A-1 Enter user name
login as: admin
Authenticating with public key "rsa-key-20101006"
IBM_4939:FlexSystem_V7000:admin>
You have now completed the tasks that are required to configure the CLI for IBM Flex System
V7000 Storage Node administration.
Example commands
A detailed description about all the available commands is beyond the intended scope of this
book. In this section are sample commands that we have referenced in this book.
With earlier releases of the IBM SAN Virtual Controller and the IBM Storwize V7000, there
were prefixes required to run CLI commands; they were svcinfo and svctask and are no
longer needed in IBM Flex System V7000 Storage Node. If you have scripts from those
platforms that use these prefixes, they run without problems. If you type svcinfo or svctask
and press the Tab key twice, all the available subcommands are listed for those prefixes.
Pressing the Tab key twice also auto-completes commands if the input is valid and unique to
the system.
Enter lsvdisk, as shown in Example A-2, to list all configured volumes on the system. The
example shows that three volumes are configured.
Example: A-2 List all volumes
IBM_4939:FlexSystem_V7000:admin>lsvdisk
id name IO_group_id IO_group_name status mdisk_grp_id mdisk_grp_name capacity type FC_id FC_name RC_id
RC_name vdisk_UID fc_map_count copy_count fast_write_state se_copy_count RC_change
0 Hyper-V_PCO_Node1 0 io_grp0 online many many 100.00GB many
600507680185853FF00000000000000F 0 2 empty 0 no
1 ESXi-PCO 0 io_grp0 online many many 100.00GB many
600507680185853FF000000000000010 0 2 empty 0 no
2 ESXi-Redbooks 0 io_grp0 online many many 400.00GB many
600507680185853FF000000000000011 0 2 not_empty 0 no
Note: When creating a public and private key with Putty and decide to use a passphrase
with the key, you will be prompted for that passphrase as shown in Example A-1.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM V7000 and is the answer not in the manual?

IBM V7000 Specifications

General IconGeneral
ModelIBM Storwize V7000
Storage TypeHybrid Flash Array
Maximum Capacity1.2PB
RAID Levels0, 1, 5, 6, 10
Connectivity8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI
ManagementCommand-line interface (CLI), Graphical user interface (GUI)
Form Factor2U
Drive Bays12
Maximum Raw Capacity1.2PB
Operating System SupportAIX, HP-UX, Linux, VMware, Windows
Data Reduction FeaturesReal-time Compression, Deduplication
Drive TypesSSD, HDD
ScalabilityScale-up (drive enclosures) and scale-out (clustering) capabilities

Related product manuals