2 Preventive Maintenance Function Configuration Procedure
17-4 WindO/I-NV4 Users Manual
This section describes the configuration procedure for the Preventive Maintenance function.
2.1 Counting Operation Time and Operation Count
1 On the Configuration tab, in the System Setup group, click Preventive Maintenance.
The Preventive Maintenance Settings dialog box is displayed.
2 Specify the number of device addresses to monitor in Number of Items.
3 Select the item to display in Settings with Display Options.
Select Operation Time + Operation Count.
The Operation Time and Operation Count settings are displayed in Settings.
4 Select the number to register the Preventive Maintenance settings to in Settings, then click Edit.
The Individual Settings dialog box is displayed.
5 Specify the bit device or the bit number of the word device to monitor with Monitor Device Address.
Click to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-68.
2 Preventive Maintenance Function Configuration Procedure
HG3G
HG2G-5FHG5G-V HG4G-V HG3G-V HG2G-V HG2G-5T
HG4G HG1G HG1P

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC MICRO/I HG1P-ST32 Series and is the answer not in the manual?

IDEC MICRO/I HG1P-ST32 Series Specifications

General IconGeneral
BrandIDEC
ModelMICRO/I HG1P-ST32 Series
CategoryControl Panel
LanguageEnglish

Related product manuals