1 Bar Chart
11-10 WindO/I-NV4 User’s Manual
When Data Over
These options configure the operation of the part when the allowable range is exceeded.
These options can only be configured when the Minimum or Maximum check boxes are selected under Range.
Example: If the word device value of the reading source is “110” which is higher than the upper limit of “100” ,or
“-10” which is below the lower limit of “0”, a value of 1 will be written to LM0 and the displayed bar will
flash.
Flash: Select this check box to make the chart flash when the displayed data exceeds the allowable range.
Report: Select this check box to write 1 in the Report Device Address when the displayed data exceeds the
allowable range.
Report Device Address: Specifies the Report Device Address.
Click to display the Tag Editor. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-68.
Ch1 data 60
Ch2 data
Ch1
Ch2
10
10 0
1
Display
20
110
50
80
10 -10
Flashing Flashing
Range: Value
Minimum: 0
Maximum: 100
When Data Over
Flash: Selected
Report: Selected
Report Device Address: LM0
Data over notification: LM0
100500 100500 100500 100500

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC MICRO/I HG1P-ST32 Series and is the answer not in the manual?

IDEC MICRO/I HG1P-ST32 Series Specifications

General IconGeneral
BrandIDEC
ModelMICRO/I HG1P-ST32 Series
CategoryControl Panel
LanguageEnglish

Related product manuals