83
5.1.4 Not aligned color print
Non-standard or bad cards :
Please change cards
(ISO CR80 card (54mm x 86mm) must be used).
Uneven or bad surface of card :
Please change cards.
Card feeding or printing roller is contaminated :
Please clean the rollers by using cleaning kit
Outdated printer :
Please contact the local supplier.
5.1.5 Unplanned color print
Non-standard or bad cards :
Please change cards
(ISO CR80 card (54mm x 86mm) must be used).
Card feeding or printing roller is contaminated :
Please clean the rollers by using cleaning kit
Malfunctioned ribbon sensors :
Please contact the local supplier to replace the sensors.
Outdated printer :
Please contact the local supplier.
Figure 109 Printing quality trouble 4
Figure 110 Printing quality trouble 5