New in the manual Revision M1
Section 1
Modification in Characteristics, pages 7 to 9.
Modification in 1-1-6-Precautions for use, page 15: use of the sample type «Other» in immunoassays.
Section 2
Modification in 2-3-1-FILE Menu, page 25: adding of a new feature accessible from this menu.
Modification in 2-3-4-MAINTENANCE Menu, page 28: adding of a new automatic maintenance accessible
from this menu
Modification in 2-3-5-SETUP Menu, page 30: adding of a new feature accessible from this menu.
Section 3
Modification in 3-3-1-Installation of internal ancillary reagents, page 47 and in 3-3-2-Installation of
external ancillary reagents, page 48: adding of automatic priming of ancillary reagents.
Modification in 3-4-System Performance Checks, pages 42 and following: programming the automatic
qualification profile now in section 7.
Adding of 3-5-1-Programming calibrations, page 55: new display options in the calibrations/controls
window.
Modification in 3-7-Programming Samples, pages 69 and following: use of the sample type «Other» in
immunoassays.
Adding of 3-8-6-Performing reflex tests, page 76.
Adding of 3-8-7-Performing dilutions, page 77: post dilutions carried out on user request.
Modification in 3-10-1-Result of a calibration, page 84: the validation criteria «calibrator CV in RLU» is
modified.
Modification in 3-10-3-Sample results, page 87: change in the reporting of results outside the measuring
range; adding of reflex test launch.
Modification in 3-10-4-Work list results, pages 87 and 88: adding of reflex test launch.
Modification in 3-11-Messages associated with results, pages 89 and following: adding of the messages
RFX and AIN; modification of messages OMR- and OMR+.
Modification in 3-12-Results Storage, pages 93 and 94: storage of incomplete profiles and removal of
stored profiles
Modification in 3-13-1-Cumulative analysis, pages 95 and following: modification in Levey-Jennings
access.
Modification in 3-14-1-Emptying the solid waste, page 101: use of disposable container.
Section 4
Modification in 4-3-Messages associated with results, pages 108 and following: adding of the messages
RFX and AIN; modification of messages OMR- and OMR+.
Section 5
Adding of 5-4-13-2-Cleaning the probe, page 145.
Section 7
Adding of Section 7: System Configuration, pages 151 and following.
Appendices
Modification in A-6- Analyser long stoppage period, pages A-8 and following.
Preface
IDS-iSYS User Manual - Revision M1" P 2
Software version V 14