List of Power Supply Unit Parameters
Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
F4-22 62486
DI7 active delay
0.00s to 600.00s 0.00 s At once
“
F4-22
”
on
page 45
F4-23 62487
DI8 active delay
0.00s to 600.00s 0.00 s At once
“
F4-23
”
on
page 45
F4-24 62488
DI1 inactive delay
0.00s to 600.00s 0.00 s At once
“
F4-24
”
on
page 45
F4-25 62489
DI2 inactive delay
0.00s to 600.00s 0.00 s At once
“
F4-25
”
on
page 45
F4-26 62490
DI3 inactive delay
0.00s to 600.00s 0.00 s At once
“
F4-26
”
on
page 46
F4-27 62491
DI4 inactive delay
0.00s to 600.00s 0.00 s At once
“
F4-27
”
on
page 46
F4-28 62492
DI5 inactive delay
0.00s to 600.00s 0.00 s At once
“
F4-28
”
on
page 46
F4-29 62493
DI6 inactive delay
0.00s to 600.00s 0.00 s At once
“
F4-29
”
on
page 46
F4-30 62494
DI7 inactive delay
0.00s to 600.00s 0.00 s At once
“
F4-30
”
on
page 46
F4-31 62495
DI8 inactive delay
0.00s to 600.00s 0.00 s At once
“
F4-31
”
on
page 47
F4-32 62496
DI (DI1 to DI5) active mode
Ones: DI1 active mode
Tens: DI2 active mode
Hundreds: DI3 active mode
Thousands: DI4 active mode
Ten thousands: DI5 active
mode
0: Active low
1: Active high
0 - At once
“
F4-32
”
on
page 47
F4-33 62497
DI (DI6 to DI8) active mode
Ones: DI6 active mode
Tens: DI7 active mode
Hundreds: DI8 active mode
0: Active low
1: Active high
0 - At once
“
F4-33
”
on
page 47
-10-