Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
F4-01 62465
DI1 function selection
0: No function
1: Forward RUN (FWD) or running
command
2: Reverse RUN (REV) or running
direction
3: Three-wire operation control
4: Forward jog (FJOG)
5: Reverse jog (RJOG)
6: Terminal UP
7: Terminal DOWN
8: UP and DOWN setting clear
(terminal, operating panel)
9: Fault reset (RESET)
10: External fault NO input
11: External fault NC input
12: User-defined fault 1
13: User-defined fault 2
14: Multi-reference terminal 1
15: Multi-reference terminal 2
16: Multi-reference terminal 3
17: Multi-reference terminal 4
18: Acceleration/deceleration selection
terminal 1
19: Acceleration/deceleration selection
terminal 2
20: Acceleration/Deceleration
prohibition
21: Command source switchover
terminal 1
22: Command source switchover
terminal 2
23: Frequency reference switchover
24: Switchover between main
frequency reference X and preset
frequency
25: Switchover between auxiliary
frequency reference Y and preset
frequency
26: Frequency modification enable
27: Counter input
28: Counter reset
1 -
At stop
F4-01
on page
245
List of Drive Unit Parameters
-150-