List of Power Supply Unit Parameters
Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
FA-86 64086
Grid voltage Usr upon the 1st
fault
- 0 V
Unchangeable
“
FA-86
”
on
page 66
FA-87 64087
Grid voltage Ust upon the 1st
fault
- 0 V
Unchangeable
“
FA-87
”
on
page 66
FA-88 64088
Grid voltage Utr upon the 1st
fault
- 0 V
Unchangeable
“
FA-88
”
on
page 66
FA-89 64089
Three-phase unbalance factor
upon the 1st fault
- 0.00 %
Unchangeable
“
FA-89
”
on
page 66
FA-90 64090
DI status upon the 1st fault
- 0 -
Unchangeable
“
FA-90
”
on
page 66
FA-91 64091
DO/RO status upon the 1st fault
- 0 -
Unchangeable
“
FA-91
”
on
page 67
FA-92 64092
Stop command sent from the
power supply unit upon the 1st
fault
1: Ready to run
2: Coast to stop
3: Stop according to preset
mode
0 -
Unchangeable
“
FA-92
”
on
page 67
FA-93 64093
Total power-on duration (hour)
upon the 1st fault
- 0
h
Unchangeable
“
FA-93
”
on
page 67
FA-94 64094
Total power-on duration
(minute) upon the 1st fault
- 0
min
Unchangeable
“
FA-94
”
on
page 67
FA-95 64095
Total power-on duration
(second) upon the 1st fault
- 0 s
Unchangeable
“
FA-95
”
on
page 67
Fd-00
64768
RS485 baud rate
0: 300 bps
1: 600 bps
2: 1200 bps
3: 2400 bps
4: 4800 bps
5: 9600 bps
6: 19200 bps
7: 38400 bps
8: 57600 bps
9: 115200 bps
5 -
At stop
“
FD-00
”
on
page 68
Fd-01
64769
RS485 data format
0: No check (8-N-2)
1: Even parity (8-E-1)
2: Odd parity (8-O-1)
3: No check (8-N-1)
4: No check (7-N-2)
5: Even parity (7-E-1)
6: Odd parity (7-O-1)
7: No check (7-N-1)
0 - At once
“
FD-01
”
on
page 68
Fd-02
64770
RS485 local address
1 to 127 16 -
Unchangeable
“
FD-02
”
on
page 69
Fd-03
64771
RS485 response delay
0 ms to 20 ms 2 ms At once
“
FD-03
”
on
page 69