List of Power Supply Unit Parameters
Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
Fd-04
64772
RS485 communication timeout
time
0.0s to 60.0s 0.0 s At once
“
FD-04
”
on
page 69
Fd-06
64774
Communication fault auto reset
0: Disabled
1: Enabled
1 - At once
“
FD-06
”
on
page 69
Fd-07
64775
Maximum station number auto
allocated
0 to 8 0 - At once
“
FD-07
”
on
page 70
Fd-09
64777
CANopen/CANlink
communication state
Ones: CANopen
0: Stop
1: Initializing
2: Pre-running
8: Running
Tens: CANlink
0: Stop
1: Initializing
2: Pre-running
8: Running
0 -
Unchangeable
“
FD-09
”
on
page 70
Fd-10
64778
Communication protocol
1: CANopen
2: CANlink
3: Communication card
mode
1 - At once
“
FD-10
”
on
page 70
Fd-12
64780
CAN baud rate
0: 20 kbps
1: 50 kbps
2: 100 kbps
3: 125 kbps
4: 250 kbps
5: 500 kbps
6: 1 Mbps
5 - At once
“
FD-12
”
on
page 71
Fd-13
64781
CAN station number
1 to 127 16 -
Unchangeable
“
FD-13
”
on
page 71
Fd-14
64782
Number of CAN frames received
per unit time (real-time)
0 to 65535 0 -
Unchangeable
“
FD-14
”
on
page 71
Fd-15
64783
Maximum value of node
reception error counter (real-
time)
0 to 65535 0 -
Unchangeable
“
FD-15
”
on
page 71
Fd-16
64784
Maximum value of node
transmission error counter (real-
time)
0 to 65535 0 -
Unchangeable
“
FD-16
”
on
page 72
Fd-17
64785
Bus-off count per unit time
0 to 65535 0 -
Unchangeable
“
FD-17
”
on
page 72
Fd-18
64786
Power supply unit number
1 to 15 1 - At once
“
FD-18
”
on
page 72
Fd-19
64787
CAN communication failure
coefficient
1 to 15 1 - At once
“
FD-19
”
on
page 72
Fd-34
64802
CANopen mode
0: Standard
1: Expert
0 - At once
“
FD-34
”
on
page 72