List of Power Supply Unit Parameters
Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
Fd-35
64803
CANopen inhibit time
0 to 65535 0 - At once
“
FD-35
”
on
page 73
Fd-36
64804
CANopen event time
0 to 65535 0 - At once
“
FD-36
”
on
page 73
Fd-39
64807
AC drive station number
configuration
0: Disabled
1: Enabled
0 - At once
“
FD-39
”
on
page 73
Fd-40
64808
Manual setting of power supply
unit station number
0 to 127 0 - At once
“
FD-40
”
on
page 73
Fd-41
64809
Manual setting of drive unit 1
station number
0 to 127 0 - At once
“
FD-41
”
on
page 73
Fd-42
64810
Manual setting of drive unit 2
station number
0 to 127 0 - At once
“
FD-42
”
on
page 73
Fd-43
64811
Manual setting of drive unit 3
station number
0 to 127 0 - At once
“
FD-43
”
on
page 74
Fd-44
64812
Manual setting of drive unit 4
station number
0 to 127 0 - At once
“
FD-44
”
on
page 74
Fd-45
64813
Manual setting of drive unit 5
station number
0 to 127 0 - At once
“
FD-45
”
on
page 74
Fd-46
64814
Manual setting of drive unit 6
station number
0 to 127 0 - At once
“
FD-46
”
on
page 74
Fd-47
64815
Manual setting of drive unit 7
station number
0 to 127 0 - At once
“
FD-47
”
on
page 74
Fd-48
64816
Manual setting of drive unit 8
station number
0 to 127 0 - At once
“
FD-48
”
on
page 75
Fd-50
64818
Startup with station lost
0: Disabled
1: Enabled
0 - At once
“
FD-50
”
on
page 75
Fd-51
64819
Slave station communication
inhibit time
0 ms to 65535 ms 0 ms
Unchangeable
“
FD-51
”
on
page 75
Fd-52
64820
Number of online slave stations
0 to 30 0 -
Unchangeable
“
FD-52
”
on
page 75
Fd-53
64821
Online status of slave stations 1
to 15
0 to 65535 0 -
Unchangeable
“
FD-53
”
on
page 75
Fd-54
64822
Online status of slave stations
16 to 31
0 to 65535 0 -
Unchangeable
“
FD-54
”
on
page 76
Fd-55
64823 PN timeout time 0 ms to 65535 ms 0 ms At once
“
FD-55
”
on
page 76
Fd-56
64824
PN chip status
0 to 65535 0 -
Unchangeable
“
FD-56
”
on
page 76
-19-