Parameter Group
-76-
Min.:
0
Unit:
-
Max.:
65535
Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
This parameter defines the online status of stations 1 to 15. Bit1 indicates station 1, and so on.
FD-54
Online status of slave stations 16 to 31
Address:
64822
Min.:
0
Unit:
-
Max.: 65535 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
This parameter defines the online status of stations 16 to 31. Bit0 indicates station 16, and so on.
FD-55
PN timeout time
Address:
64823
Min.:
0
Unit:
ms
Max.: 65535 Data type: UInt16
Default:
0
Change:
At once
Value Range:
0 ms to 65535 ms
Description
This parameter defines the PROFINET communication timeout time.
FD-56
PN chip state
Address:
64824
Min.:
0
Unit:
-
Max.: 65535 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
This parameter defines the state of the PRFOFINET chip.
FD-57
Communication card state
Address:
64825
Min.:
0
Unit:
-
Max.: 65535 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0: Initializing
1: Running
2: Stop
3: Reconnecting
Description
This parameter defines the state of the communication card.