List of Power Supply Unit Parameters
Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
Fd-57
64825
Communication card status
0: Initializing
1: Running
2: Stop
3: Reconnecting
0 -
Unchangeable
“
FD-57
”
on
page 76
Fd-61
64829
MAC address 1
0 to 65535 0 -
Unchangeable
“
FD-61
”
on
page 77
Fd-62
64830
MAC address 2
0 to 65535 0 -
Unchangeable
“
FD-62
”
on
page 77
Fd-63
64831
MAC address 3
0 to 65535 0 -
Unchangeable
“
FD-63
”
on
page 77
Fd-70
64838
EtherCAT station name
0 to 65535 0 -
Unchangeable
“
FD-70
”
on
page 77
Fd-71
64839
EtherCAT station alias
0 to 65535 0 - At once
“
FD-71
”
on
page 77
Fd-72
64840
Number of synchronization
interrupts allowed by EtherCAT
0 to 30 10 - At once
“
FD-72
”
on
page 77
Fd-73
64841
EtherCAT - Port0 CRC error
0 to 65535 0 -
Unchangeable
“
FD-73
”
on
page 78
Fd-74
64842
EtherCAT - Port1 CRC error
0 to 65535 0 -
Unchangeable
“
FD-74
”
on
page 78
Fd-75
64843
EtherCAT port 0/1 data
forwarding error
0 to 65535 0 -
Unchangeable
“
FD-75
”
on
page 78
Fd-76
64844
EtherCAT processing unit and
PDI error
0 to 65535 0 -
Unchangeable
“
FD-76
”
on
page 78
Fd-77
64845
EtherCAT port 0/1 link loss
0 to 65535 0 -
Unchangeable
“
FD-77
”
on
page 78
Fd-78
64846
EtherCAT master type
0 to 65535 0 - At once
“
FD-78
”
on
page 79
Fd-79
64847
EtherCAT synchronization error
monitoring mode
0 to 1 0 - At once
“
FD-79
”
on
page 79
Fd-80
64848
EtherCAT synchronization frame
loss count
0 to 65535 0 -
Unchangeable
“
FD-80
”
on
page 79
Fd-81
64849
EtherCAT state machine and
PHYLink status
0 to 65535 0 -
Unchangeable
“
FD-81
”
on
page 79
Fd-82
64850
EtherCAT - AL fault code
0: No error
1 to 0xFFFF: Error status
code
0 -
Unchangeable
“
FD-82
”
on
page 79
Fd-83
64851
EtherCAT - XML file version
0.00 to 655.35 0.00 -
Unchangeable
“
FD-83
”
on
page 80
Fd-84
64852
EtherCAT - FPGA firmware
version
0 to 65535 0 -
Unchangeable
“
FD-84
”
on
page 80
-20-