EasyManua.ls Logo

Inovance MD800 Series - Page 189

Inovance MD800 Series
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
A1-00 41216
VDI1 function
0: No function
1: Forward RUN (FWD)
2: Reverse RUN (REV)
3: Three-wire operation control
4: Forward jog (FJOG)
5: Reverse jog (RJOG)
6: Terminal UP
7: Terminal DOWN
8: UP and DOWN setting clear
(terminal, operating panel)
9: Fault reset (RESET)
10: External fault NO input
11: External fault NC input
12: User-defined fault 1
13: User-defined fault 2
14: Multi-reference terminal 1
15: Multi-reference terminal 2
16: Multi-reference terminal 3
17: Multi-reference terminal 4
18: Acceleration/deceleration selection
terminal 1
19: Acceleration/deceleration selection
terminal 2
20: Acceleration/Deceleration
prohibition
21: Command source switchover
terminal 1
22: Command source switchover
terminal 2
23: Frequency reference switchover
24:Switchover between main
frequency reference X and preset
frequency
25: Switchover between auxiliary
frequency reference Y and preset
frequency
26: Frequency modification enable
27: Counter input
28: Counter reset
0 -
At stop
A1-00
on page
351
List of Drive Unit Parameters
-188-

Table of Contents

Other manuals for Inovance MD800 Series

Related product manuals