Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
A0-09 40969
Speed limit reference
source
0: A0-05
1: Frequency source
0 - At once
A0-09
on page
350
A0-10 40970
Speed limit offset
0.00 to 655.35 5.00 - At once
A0-10
on page
350
A0-11 40971
Effective mode of speed
limit offset
0: Bidirectional offset effective
1: Unidirectional offset effective
0 -
At stop
A0-11
on page
350
A0-12 40972
Acceleration time
(frequency)
0.0s to 6500.0s 1.0 s At once
A0-12
on page
350
A0-13 40973
Deceleration time
(frequency)
0.0s to 6500.0s 1.0 s At once
A0-13
on page
350
A0-14 40974
Torque mode switchover
0: Not switched
1: Switched to speed mode upon stop
2: Target torque changed to 0 upon
stop
1 -
At stop
A0-14
on page
351