Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
A9-45 0xA92D
Synchronous motor low-
speed handling
0: Disabled
1: Enabled
0 -
At stop
“
A9-45
”
on page
369
A9-46 0xA92E
Switchover frequency for
synchronous motor low-
speed handling
0.01 to 5.99 5 -
At stop
“
A9-46
”
on page
369
A9-47 0xA92F
Synchronous motor low-
speed handling current
10 to 200 100 -
At stop
“
A9-47
”
on page
369
A9-48 0xA930
Synchronous motor low-
speed handling feedback
suppression coefficient
0 to 300 32 -
At stop
“
A9-48
”
on page
369
A9-51 0xA933
Advanced settings for
asynchronous motor
parameter auto-tuning
Ones: Rotor resistance and leakage
inductance DC offset
0: Standard offset
1: Large offset
Tens: New rotor resistance and
leakage inductance auto-tuning
algorithm
0: Disabled
1: Enabled
Hundreds: New mutual inductance
static auto-tuning algorithm
0: Disabled
1: Enabled
Thousands: Stator resistance auto-
tuning algorithm
0: Current open loop
1: Current closed loop
111 -
At stop
“
A9-51
”
on page
369
AF-00 44800
RPDO1-SubIndex0-H
0 to 65535 0 - At once
“
AF-00
”
on page
370
AF-01 44801
RPDO1-SubIndex0-L
0 to 65535 0 - At once
“
AF-01
”
on page
370
AF-02 44802
RPDO1-SubIndex1-H
0 to 65535 0 - At once
“
AF-02
”
on page
370
AF-03 44803
RPDO1-SubIndex1-L
0 to 65535 0 - At once
“
AF-03
”
on page
370
AF-04 44804
RPDO1-SubIndex2-H
0 to 65535 0 - At once
“
AF-04
”
on page
371
AF-05 44805
RPDO1-SubIndex2-L
0 to 65535 0 - At once
“
AF-05
”
on page
371
List of Drive Unit Parameters