Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
A9-21 43285
Field-weakening gain of
synchronous motor
0 to 50 5 - At once
A9-21
on page
366
A9-22 43286
Output voltage upper
limit margin of
synchronous motor
0% to 50% 5 % At once
A9-22
on page
366
A9-23 43287
Maximum output
adjustment gain of
synchronous motor
20% to 300% 100 % At once
A9-23
on page
366
A9-24 43288
Exciting current
adjustment gain
calculated by
synchronous motor
40% to 200% 100 % At once
A9-24
on page
366
A9-25 43289
Estimated synchronous
motor speed integral
gain in SVC mode
5 to 1000 30 - At once
A9-25
on page
366
A9-26 43290
Estimated synchronous
motor speed
proportional gain in SVC
mode
5 to 300 20 - At once
A9-26
on page
367
A9-27 43291
Estimated synchronous
motor speed filter in SVC
mode
10 to 2000 100 - At once
A9-27
on page
367
A9-28 43292
Minimum carrier
frequency of
synchronous motor in
SVC mode
8 to 65535 20 - At once
A9-28
on page
367
A9-29 43293
Low-speed excitation
current of synchronous
motor in SVC mode
0% to 80% 30 % At once
A9-29
on page
367
A9-40 43304
Low-speed closed-loop
current selection (for
VVC)
0: Disabled
1: Enabled
0 -
At stop
A9-40
on page
367
A9-41 43305
Low-speed closed-loop
current (for VVC)
30 to 200 50 -
At stop
A9-41
on page
368
A9-42 43306
Oscillation suppression
damping coefficient (for
VVC)
0 to 500 100 - At once
A9-42
on page
368
A9-43 43307
Initial position
compensation angle (for
VVC)
0 to 5 0 -
At stop
A9-43
on page
368
A9-44 0xA92C
Initial position
compensation angle of
synchronous motor
0 to 360 0 - In real time
A9-44
on page
368