Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
A9-07 43271
Field control bandwidth
of asynchronous motor
in SVC mode
0.0 to 8.0 2.0 - At once
“
A9-07
”
on page
363
A9-08 43272
Low-speed running
current of asynchronous
motor in SVC mode
30 to 170 100 - At once
“
A9-08
”
on page
363
A9-09 43273
Switchover frequency of
output fixed current of
asynchronous motor in
SVC mode
2.0 Hz to 100.0 Hz 3.0 Hz At once
“
A9-09
”
on page
363
A9-10 43274
Speed fluctuation
suppression coefficient
of asynchronous motor
in SVC mode
0 to 6 3 - At once
“
A9-10
”
on page
364
A9-11 43275
Acceleration/
Deceleration time of
asynchronous motor in
SVC mode
0.1s to 3000.0s 20.0 s At once
“
A9-11
”
on page
364
A9-12 43276
Quick auto-tuning of
stator resistance before
asynchronous motor
startup
0: Disabled
1: Enabled
0 - At once
“
A9-12
”
on page
364
A9-13 43277
Coefficient 1 of quick
auto-tuning of
asynchronous motor
stator resistance
0 to 65535 10 -
At stop
“
A9-13
”
on page
364
A9-14 43278
Coefficient 2 of quick
auto-tuning of
asynchronous motor
stator resistance
0 to 65535 10 -
At stop
“
A9-14
”
on page
364
A9-15 43279
Coefficient 3 of quick
auto-tuning of
asynchronous motor
stator resistance
0 to 65535 0 -
At stop
“
A9-15
”
on page
365
A9-17 43281
Synchronous motor real-
time angle
0 to 65535 0 -
Unchangeable
“
A9-17
”
on page
365
A9-18 43282
Initial angle detection of
synchronous motor
0: Detected upon running
1: Not detected
2: Detected upon initial running after
power-on
0 - At once
“
A9-18
”
on page
365
A9-20 43284
Field weakening mode
0: Automatic mode
1: Synchronous motor adjustment
mode
2: Synchronous motor hybrid mode
3: Disabled
1 -
At stop
“
A9-20
”
on page
365
List of Drive Unit Parameters