Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
A6-19 42515
AI2 offset
–100.0% to 100.0% 0.0 % At once
“
A6-19
”
on page
360
A6-20 42516
AI3 gain
–10.00 to 10.00 1.00 - At once
“
A6-20
”
on page
360
A6-21 42517
AI3 offset
–100.0% to 100.0% 0.0 % At once
“
A6-21
”
on page
360
A6-24 42520
Jump point of AI1 setting
–100.0% to 100.0% 0.0 % At once
“
A6-24
”
on page
361
A6-25 42521
Jump amplitude of AI1
setting
0.0% to 100.0% 0.5 % At once
“
A6-25
”
on page
361
A6-26 42522
Jump point of AI2 setting
–100.0% to 100.0% 0.0 % At once
“
A6-26
”
on page
361
A6-27 42523
Jump amplitude of AI2
setting
0.0% to 100.0% 0.5 % At once
“
A6-27
”
on page
361
A6-28 42524
Jump point of AI3 setting
–100.0% to 100.0% 0.0 % At once
“
A6-28
”
on page
361
A6-29 42525
Jump amplitude of AI3
setting
0.0% to 100.0% 0.5 % At once
“
A6-29
”
on page
362
A9-00 43264
Online auto-tuning on
rotor time constant of
asynchronous motor
0: Disabled
1: Enabled
0 - At once
“
A9-00
”
on page
362
A9-04 43268
Maximum torque limit
coefficient for the
asynchronous motor
field-weakening range
30 to 150 80 - At once
“
A9-04
”
on page
362
A9-05 43269
Speed filter of
asynchronous motor in
SVC mode
5 ms to 32 ms 15 ms At once
“
A9-05
”
on page
362
A9-06 43270
Asynchronous motor
speed feedback
processing in SVC mode
0: No specific processing
1: Limit minimum synchronization
frequency based on load change
2: Output fixed current during low-
speed running
3: Output fixed current during low-
speed running
0 - At once
“
A9-06
”
on page
363
List of Drive Unit Parameters