Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
U0-00 28672
Running frequency 0.00 Hz to target frequency
Model
dependent
Hz
Unchangeable
U0-00
on page
383
U0-01 28673
Frequency reference 0.00 Hz to target frequency
Model
dependent
Hz
Unchangeable
U0-01
on page
383
U0-02 28674
Bus voltage
0.0 V to 3000.0 V
Model
dependent
V
Unchangeable
U0-02
on page
383
U0-03 28675
Output voltage
0 V to 1140 V
Model
dependent
V
Unchangeable
U0-03
on page
383
U0-04 28676
Output current
0.00 A to 655.35 A
Model
dependent
A
Unchangeable
U0-04
on page
383
U0-05 28677
Output power
0.0 kW to 3276.7 kW
Model
dependent
kW
Unchangeable
U0-05
on page
384
U0-06 28678
Output torque
–200.0% to +200.0%
Model
dependent
%
Unchangeable
U0-06
on page
384
U0-07 28679 DI state -
Model
dependent
-
Unchangeable
U0-07
on page
384
U0-08 28680
DO/RO state
-
Model
dependent
-
Unchangeable
U0-08
on page
384
U0-09 28681
AI1 voltage
–10.00 V to 10.00 V
Model
dependent
V
Unchangeable
U0-09
on page
385
U0-10 28682
AI2 voltage
–10.00 V to 10.00 V
Model
dependent
V
Unchangeable
U0-10
on page
385
U0-11 28683
AI3 voltage
–10.00 V to 10.00 V
Model
dependent
V
Unchangeable
U0-11
on page
385
U0-12 28684
Count value
1 to 65535
Model
dependent
-
Unchangeable
U0-12
on page
385
U0-13 28685
Length value
1 to 65535
Model
dependent
-
Unchangeable
U0-13
on page
385
U0-14 28686
Load speed display 0 to rated motor speed
Model
dependent
-
Unchangeable
U0-14
on page
386