Parameter Group
-224-
Min.:
1
Unit:
mH
Max.:
65535
Data type: UInt16
Default: Model dependent Change:
At stop
Value Range:
1mH to 65535mH
Description
This parameter defines the inductance of the main pole axis (longitudinal axis) of the synchronous
motor.
F1-18
Synchronous motor axis Q inductance
Address:
61714
Min.:
1
Unit:
mH
Max.: 65535 Data type: UInt16
Default: Model dependent Change:
At stop
Value Range:
1mH to 65535mH
Description
This parameter defines the inductance of the center line (quadrature axis) between the adjacent pole
axes of the synchronous motor rotor.
F1-19
Synchronous motor back EMF coefficient
Address:
61715
Min.:
0.1
Unit:
V
Max.:
6553.5
Data type: UInt16
Default: Model dependent Change:
At stop
Value Range:
0.1V to 6553.5V
Description
This parameter defines the valid value of the motor back EMF at the rated frequency (F1-04).
F1-24
Number of motor pole pairs
Address:
61720
Min.:
0
Unit:
-
Max.: 65535 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
This parameter defines the number of motor pole pairs.
F1-37
Auto-tuning
Address:
61733
Min.:
0
Unit:
-
Max.: 14 Data type: UInt16
Default:
0
Change:
At stop
Value Range: