List of Power Supply Unit Parameters
Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
A0-08 40968
Axis 4 - frame loss count
0 to 65535 0 -
Unchangeable
“
A0-08
”
on
page 87
A0-09 40969
Axis 5 - frame loss count
0 to 65535 0 -
Unchangeable
“
A0-09
”
on
page 87
A0-10 40970
Axis 6 - frame loss count
0 to 65535 0 -
Unchangeable
“
A0-10
”
on
page 87
A0-11 40971
Axis 7 - frame loss count
0 to 65535 0 -
Unchangeable
“
A0-11
”
on
page 88
A0-12 40972
Axis 8 - frame loss count
0 to 65535 0 -
Unchangeable
“
A0-12
”
on
page 88
A0-13 40973
Extension card 1 - frame loss
count
0 to 65535 0 -
Unchangeable
“
A0-13
”
on
page 88
A0-14 40974
Extension card 2 - frame loss
count
0 to 65535 0 -
Unchangeable
“
A0-14
”
on
page 88
A0-15 40975
Extension card 3 - frame loss
count
0 to 65535 0 -
Unchangeable
“
A0-15
”
on
page 88
A1-00 41216
Power supply unit - filter time of
DI1 to DI4
0.000s to 5.000s 0.010 s At once
“
A1-00
”
on
page 89
A1-01 41217
Power supply unit - filter time of
DI5 to DI8
0.000s to 5.000s 0.010 s At once
“
A1-01
”
on
page 89
A1-05 41221
AI1 filter time
0.00s to 10.00s 0.10 s At once
“
A1-05
”
on
page 89
A1-06 41222
AI2 filter time
0.00s to 10.00s 0.10 s At once
“
A1-06
”
on
page 89
A1-10 41226
AI1 input
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
0 -
At stop
“
A1-10
”
on
page 89
A1-11 41227
AI2 input
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
0 -
At stop
“
A1-11
”
on
page 90
A2-00 41472
Extension card 1 - filter time of
DI1 to DI4
0.000s to 5.000s 0.010 s At once
“
A2-00
”
on
page 90
A2-01 41473
Extension card 1 - filter time of
DI5 to DI8
0.000s to 5.000s 0.010 s At once
“
A2-01
”
on
page 90
A2-05 41477
AI1 filter time
0.00s to 10.00s 0.10 s At once
“
A2-05
”
on
page 91
-23-