List of Power Supply Unit Parameters
Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
A2-06 41478
AI2 filter time
0.00s to 10.00s 0.10 s At once
“
A2-06
”
on
page 91
A2-10 41482
AI1 input
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
0 -
At stop
“
A2-10
”
on
page 91
A2-11 41483
AI2 input
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
0 -
At stop
“
A2-11
”
on
page 91
A3-00 41728
Extension card 2 - filter time of
DI1 to DI4
0.000s to 5.000s 0.010 s At once
“
A3-00
”
on
page 92
A3-01 41729
Extension card 2 - filter time of
DI5 to DI8
0.000s to 5.000s 0.010 s At once
“
A3-01
”
on
page 92
A3-05 41733
AI1 filter time
0.00s to 10.00s 0.10 s At once
“
A3-05
”
on
page 92
A3-06 41734
AI2 filter time
0.00s to 10.00s 0.10 s At once
“
A3-06
”
on
page 92
A3-10 41738
AI1 input
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
0 -
At stop
“
A3-10
”
on
page 92
A3-11 41739
AI2 input
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
0 -
At stop
“
A3-11
”
on
page 93
AC-00 44032
Power supply unit - AI1
measured voltage 1
0.000V to 12.000V 2.000 V At once
“
AC-00
”
on
page 93
AC-01 44033
Power supply unit - AI1
displayed voltage 1
0.000V to 12.000V 2.000 V At once
“
AC-01
”
on
page 93
AC-02 44034
Power supply unit - AI1
measured voltage 2
0.000V to 12.000V 2.000 V At once
“
AC-02
”
on
page 94
AC-03 44035
Power supply unit - AI1
displayed voltage 2
0.000V to 12.000V 2.000 V At once
“
AC-03
”
on
page 94
AC-04 44036
Power supply unit - AI2
measured voltage 1
0.000V to 12.000V 2.000 V At once
“
AC-04
”
on
page 94
-24-