Parameter Group
-276-
F7-04
LED display 2 in running state
Address:
63236
Min.:
0
Unit:
-
Max.:
65535
Data type: UInt16
Default:
0
Change:
At once
Value Range:
Bit00: PID feedback
Bit01: PLC stage
Bit02: Reserved
Bit03: Running frequency 2 (Hz)
Bit04: Remaining running time
Bit05: Reserved
Bit06: Reserved
Bit07: Reserved
Bit08: Linear speed
Bit09: Current power-on time (min)
Bit10: Current running time (min)
Bit11: Reserved
Bit12: Communication
Bit13: Reserved
Bit14: Main frequency X
Bit15: Auxiliary frequency Y
Description
To display a parameter during running, set the corresponding bit to 1, convert the binary number to a
hexadecimal equivalent, and set it in F7-04.
F7-05
LED display in stop state
Address:
63237
Min.:
0
Unit:
-
Max.: 65535 Data type: UInt16
Default:
51
Change:
At once
Value Range:
Bit00: Frequency reference (Hz)
Bit01: Bus voltage (V)
Bit02: DI state
Bit03: DO state
Bit04: AI1 voltage (V)
Bit05: AI2 voltage (V)
Bit06: AI3 voltage (V)
Bit07: Count value
Bit08: Length value
Bit09: PLC stage
Bit10: Load speed
Bit11: PID reference
Bit12: Reserved
Description
To display a parameter upon stop, set the corresponding bit to 1, convert the binary number to a
hexadecimal equivalent, and set it in F7-05.