Parameter Group
-293-
F8-62
Load speed display coefficient
Address:
63550
Min.:
1E-4
Unit:
-
Max.: 6.5000 Data type: UInt16
Default:
1.0000
Change:
At once
Value Range:
0.0001 to 6.5000
Description
This parameter defines the ratio of the actual with-load speed to motor speed.
F8-63
Number of decimal places for load speed display
Address:
63551
Min.:
0
Unit:
-
Max.: 3 Data type: UInt16
Default:
1
Change:
At once
Value Range:
0: 0 decimal places
1: 1 decimal place
2: 2 decimal places
3: 3 decimal places
Description
The ones place of this parameter defines the number of decimal places of the value U0-14 (load
speed).
0: 0 decimal places
No decimal places are retained.
1: 1 decimal place
The value is rounded to one decimal place.
2: 2 decimal places
The value is rounded to two decimal places.
3: 3 decimal places
The value is rounded to three decimal places.
F8-64
7310H address data unit
Address:
63552
Min.:
0
Unit:
-
Max.: 1 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Frequency (Hz)
1: Speed (RPM)
Description
This parameter defines the unit of data written to the address 7310.
0: Frequency (Hz)
The unit of the written data is Hz.
1: Speed (RPM)
The unit of the written data is RPM.