Parameter Group
-322-
Description
0: Relative to center frequency (F0-07, frequency reference superposition). This mode applies to
variable swing systems, in which the swing changes with the center frequency (frequency reference).
1: Relative to the maximum frequency (F0-10, maximum frequency). This mode applies to fixed swing
systems, in which the swing is a fixed value calculated based on the maximum frequency.
FB-01
Wobble amplitude
Address:
64257
Min.:
0.0
Unit:
%
Max.: 100.0 Data type: UInt16
Default:
0.0
Change:
At once
Value Range:
0.0% to 100.0%
Description
When Fb-01 is set to 0, the wobble amplitude is 0, indicating that the wobble function is disabled.
FB-02
Wobble step
Address:
64258
Min.:
0.0
Unit:
%
Max.: 50.0 Data type: UInt16
Default:
0.0
Change:
At once
Value Range:
0.0% to 50.0%
Description
This parameter defines the wobble amplitude and step. The wobble running frequency is limited by
the frequency upper limit and frequency lower limit.
FB-03
Wobble cycle
Address:
64259
Min.:
0.1
Unit:
s
Max.:
3000.0
Data type: UInt16
Default:
10.0
Change:
At once
Value Range:
0.1s to 3000.0s
Description
This parameter defines the time of a complete wobble cycle.
FB-04
Triangular wave rise time coefficient
Address:
64260
Min.:
0.1
Unit:
%
Max.: 100.0 Data type: UInt16
Default:
50.0
Change:
At once
Value Range:
0.1% to 100.0%
Description
This parameter defines the percentage of the triangular wave rise time relative to the wobble cycle
(Fb-03).
FB-05
Reference length
Address:
64261
Min.:
0
Unit:
m