Parameter Group
-323-
Max.: 65535 Data type: UInt16
Default:
1000
Change:
At once
Value Range:
0 m to 65535 m
Description
This parameter specifies the length value to be controlled in fixed length control mode.
FB-06
Actual length
Address:
64262
Min.:
0
Unit:
m
Max.: 65535 Data type: UInt16
Default:
0
Change:
At once
Value Range:
0 m to 65535 m
Description
The actual length is a monitored value. Actual length (Fb-06) = Number of pulses sampled by DI/
Number of pulses per meter (Fb-07).
FB-07
Number of pulses per meter
Address:
64263
Min.:
0.1
Unit:
-
Max.: 6553.5 Data type: UInt16
Default:
100.0
Change:
At once
Value Range:
0.1 to 6553.5
Description
This parameter defines the number of pulses output per meter. The length pulses are sampled by a DI
terminal assigned with function 29 (length count input).
FB-08
Reference count value
Address:
64264
Min.:
1
Unit:
-
Max.:
65535
Data type: UInt16
Default:
1000
Change:
At once
Value Range:
1 to 65535
Description
When the count value reaches Fb-08, the DO terminal outputs an active signal indicating that the
reference count value is reached.
FB-09
Designated count value
Address:
64265
Min.:
1
Unit:
-
Max.: 65535 Data type: UInt16
Default:
1000
Change:
At once
Value Range:
1 to 65535
Description
When the count value reaches Fb-09, the DO terminal outputs an active signal indicating that the
designated count value is reached. Fb-09 must be less than or equal to Fb-08 (reference count value).