FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-29
Acceleration/Deceleration time of PLC reference 5
Address:
64541
Min.:
0
Unit:
-
Max.: 3 Data type: UInt16
Default:
0
Change:
At once
Value Range:
0 to 3
Description
FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-30
Running time of PLC reference 6
Address:
64542
Min.:
0.0
Unit:
s (h)
Max.:
6553.5
Data type:
UInt16
Default:
0.0
Change:
At once
Value Range:
0.0s (h) to 6553.5s (h)
Description
FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-31
Acceleration/Deceleration time of PLC reference 6
Address:
64543
Min.:
0
Unit:
-
Max.: 3 Data type: UInt16
Default:
0
Change:
At once
Value Range:
0 to 3
Description
FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-32
Running time of PLC reference 7
Address:
64544
Min.:
0.0
Unit:
s (h)
Max.: 6553.5 Data type: UInt16
Default:
0.0
Change:
At once
Value Range:
0.0s (h) to 6553.5s (h)