EasyManua.ls Logo

Inovance MD800 Series - Page 333

Inovance MD800 Series
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Group
-332-
Description
FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-33
Acceleration/Deceleration time of PLC reference 7
Address:
64545
Min.:
0
Unit:
-
Max.: 3 Data type: UInt16
Default:
0
Change:
At once
Value Range:
0 to 3
Description
FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-34
Running time of PLC reference 8
Address:
64546
Min.:
0.0
Unit:
s (h)
Max.:
6553.5
Data type:
UInt16
Default:
0.0
Change:
At once
Value Range:
0.0s (h) to 6553.5s (h)
Description
FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-35
Acceleration/Deceleration time of PLC reference 8
Address:
64547
Min.:
0
Unit:
-
Max.: 3 Data type: UInt16
Default:
0
Change:
At once
Value Range:
0 to 3
Description
FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-36
Running time of PLC reference 9
Address:
64548
Min.:
0.0
Unit:
s (h)
Max.: 6553.5 Data type: UInt16
Default:
0.0
Change:
At once
Value Range:
0.0s (h) to 6553.5s (h)

Table of Contents

Other manuals for Inovance MD800 Series

Related product manuals