Parameter Group
-335-
Description
FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-45
Acceleration/Deceleration time of PLC reference 13
Address:
64557
Min.:
0
Unit:
-
Max.: 3 Data type: UInt16
Default:
0
Change:
At once
Value Range:
0 to 3
Description
FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-46
Running time of PLC reference 14
Address:
64558
Min.:
0.0
Unit:
s (h)
Max.:
6553.5
Data type:
UInt16
Default:
0.0
Change:
At once
Value Range:
0.0s (h) to 6553.5s (h)
Description
FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-47
Acceleration/Deceleration time of PLC reference 14
Address:
64559
Min.:
0
Unit:
-
Max.: 3 Data type: UInt16
Default:
0
Change:
At once
Value Range:
0 to 3
Description
FC-18 to FC-49 define the operation time and acceleration/deceleration time of each of the 16 multi-
speed references respectively. The operation duration of each reference is the sum of the acceleration
or deceleration time plus the time of operation at constant speed and target frequency.
FC-48
Running time of PLC reference 15
Address:
64560
Min.:
0.0
Unit:
s (h)
Max.: 6553.5 Data type: UInt16
Default:
0.0
Change:
At once
Value Range:
0.0s (h) to 6553.5s (h)