Function Applications
-543-
Para. No. Name
Basic Unit
Value Range Description
U0-23
AI3 voltage
after gain and
offset
0.01 V –10.00 V to 10.00 V
Voltage (V) of AI3 after gain and offset
U0-24
Linear speed
1 m/min
0 m/min to 65535 m/
min
U0-25
Current power-
on time
1 min 0 min to 65000 min
Duration (min) from power-on to the current
time
U0-26
Current
running time
0.1 min 0.0 min to 6500.0 min
Duration (min) from power-on to the current
time
U0-28
Communica-
tion
0.01% –100.00% to 100.00%
Data written through the communication
address 0x1000. The percentage base is
determined by the value set in address
0x1000.
U0-30
Main frequency
X display
0.01 Hz 0.00 Hz to 500.00 Hz
Main frequency (Hz) of the AC drive
U0-31
Auxiliary
frequency Y
display
0.01 Hz 0.00 Hz to 500.00 Hz
Auxiliary frequency (Hz) of the AC drive
U0-33
Synchronous
motor rotor
position
0.19° 0.0° to 359.9°
-
U0-35
Target torque
0.10% –200.0% to +200.0%
Current torque upper limit. The percentage
base is the rated motor torque.
U0-37
Power factor
angle
0.1° 0.0° to 6553.5°
Current power factor angle
U0-39
Target voltage
upon V/f
separation
1 V
0 V to target voltage
Target output voltage in V/f separation
mode
U0-40
Output voltage
upon V/f
separation
1 V
0 V to output voltage
Current actual output voltage in V/f
separation mode
U0-41
DI state display
1 0 to 65535
State of the DI terminal: ON indicates high
level and OFF indicates low level.
AI2
AI3
VDI5
AI1-DI
VDI3
DI8
DI3
DI4
DI1VDI1 DI7 DI5
VDI4
VDI2 DI6 DI2
U0-42
DO/RO state
display
1 0 to 65535
State of the DO/RO terminal: ON indicates
high level and OFF indicates low level.