Function Applications
-544-
Para. No. Name
Basic Unit
Value Range Description
U0-43
DI function
state display 1
1 0 to 65535
Validity of terminal functions 1 to 40. The
operating panel has five LEDs, which
indicate functions 1–8, 9–16, 17–24, 25–32,
and 33–40 respectively from right to left.
Each LED displays selection of eight
functions, as shown in the following figure.
ON indicates high level and OFF indicates
low level.
U0-44
DI function
state display 2
1 0 to 65535
Validity of terminal functions 41 to 59. The
operating panel has five LEDs, which
indicate functions 41–48, 49–56, and 57–59
respectively from right to left. Each LED
displays selection of eight functions, as
shown in the following figure.
ON indicates high level and OFF indicates
low level.
U0-45
Fault code
1 0 to 51
Fault code of the AC drive
U0-46
Fault subcode
1 0 to 51
Fault subcode of the AC drive
U0-47
Drive unit
temperature
1°C -20°C to 120°C
Heatsink temperature of the IGBT
U0-48
Voltage
received
through PTC
channel 1
0.001 V
-
Voltage (V) received from the power supply
unit when AI1 is used for temperature sensor
input
U0-49
Voltage
received
through PTC
channel 2
0.001 V
-
Voltage (V) received from the power supply
unit when AI2 is used for temperature sensor
input
U0-50
Voltage
received
through PTC
channel 3
0.001 V
-
Voltage (V) received from the power supply
unit when AI3 is used for temperature sensor
input
U0-51
PTC1
temperature
1°C
-
Temperature (°C) calculated when AI1 is
used for temperature sensor input
U0-52
PTC2
temperature
1°C
-
Temperature (°C) calculated when AI2 is
used for temperature sensor input
U0-53
PTC3
temperature
1°C
-
Temperature (°C) calculated when AI3 is
used for temperature sensor input
U0-54
Motor speed
1 RPM
-
Current motor speed (RPM)
U0-55
Station
number auto
allocated
1
-
Station number that is automatically
assigned