Parameter Group
-95-
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI2, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI2 voltage before
correction (U2-13).
AC-06
Power supply unit - AI2 measured voltage 2
Address:
44038
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI2, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI2 voltage before
correction (U2-13).
AC-07
Power supply unit - AI2 displayed voltage 2
Address:
44039
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI2, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI2 voltage before
correction (U2-13).
AC-08
Extension card 1 - AI1 measured voltage 1
Address:
44040
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI1, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI1 voltage before
correction (U3-12).
AC-09
Extension card 1 - AI1 displayed voltage 1
Address:
44041
Min.:
0.000
Unit:
V