Parameter Group
-97-
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI1, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI1 voltage before
correction (U3-13).
AC-14
Extension card 1 - AI2 measured voltage 2
Address:
44046
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI1, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI1 voltage before
correction (U3-13).
AC-15
Extension card 1 - AI2 displayed voltage 2
Address:
44047
Min.:
0.000
Unit:
V
Max.:
12.000
Data type:
UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI1, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI1 voltage before
correction (U3-13).
AC-16
Extension card 2 - AI1 measured voltage 1
Address:
44048
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI1, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI1 voltage before
correction (U4-12).