EasyManuals Logo

Juniper EX4300 Series User Manual

Juniper EX4300 Series
415 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #135 background imageLoading...
Page #135 background image
Table 54: EX Series Switch Environmental Tolerances
Switch or
device
Environment Tolerance
Altude Relave Humidity Temperature Seismic
EX2200-C
No performance
degradaon up to
5,000 feet (1524
meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon ensured
in the temperature range
32° F (0° C) through
104° F (40° C) at
altudes up to 5,000
(1,524 m).
For informaon about
extended temperature
SFP transceivers
supported on EX2200
switches, see Pluggable
Transceivers Supported
on EX2200 Switches.
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX2200
(except
EX2200-C
switches)
No performance
degradaon up to
10,000 feet
(3048 meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon ensured
in the temperature range
32° F (0° C) through
113° F (45° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX2300-C No performance
degradaon up to
5,000 feet
(1524 meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon ensured
in the temperature range
32° F (0° C) through
104° F (40° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX2300
(except
EX2300-C
switches)
No performance
degradaon up to
13,000 feet
(3962 meters) at
104° F (40° C) as
per GR-63
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon ensured
in the temperature range
32° F (0° C) through
113° F (45° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
125

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4300 Series and is the answer not in the manual?

Juniper EX4300 Series Specifications

General IconGeneral
Product SeriesEX4300 Series
Power ConsumptionVaries by model and configuration
Virtual Chassis TechnologyUp to 10 switches
SoftwareJunos OS
Ports24-port and 48-port models
10GBASE SFP+ PortsUp to 8 ports
40GBASE QSFP+ Ports2
Uplink PortsUp to 4 ports
Jumbo FramesUp to 9216 bytes
Operating Temperature0°C to 45°C
Relative Humidity5% to 90% noncondensing
Input Voltage100 to 240V AC
Power SupplyAC or DC
Power Supply OptionsAC or DC
StackingYes
Layer 2 FeaturesIncludes VLAN, STP, RSTP, MSTP, LACP
Layer 3 FeaturesOSPF, BGP
ManagementCLI, Web GUI, SNMP
Security FeaturesDHCP snooping
QoS8 queues per port, DSCP
Storage Temperature-40°C to 70°C