EasyManuals Logo

Juniper EX4300 Series User Manual

Juniper EX4300 Series
415 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #400 background imageLoading...
Page #400 background image
CC, meere l'interruore in posizione OFF e ssarlo con nastro adesivo in tale
posizione.
Advarsel Før noen av disse prosedyrene uøres, kontroller at strømmen er frakoblet
likestrømkretsen. Sørg for at all strøm er slå AV. Dee gjøres ved å lokalisere
strømbryteren på brytertavlen som betjener likestrømkretsen, slå strømbryteren AV og
teipe bryterhåndtaket på strømbryteren i AV-slling.
Aviso Antes de executar um dos seguintes procedimentos, cerque-se que desligou a
fonte de alimentação de energia do circuito de corrente connua. Para se assegurar que
toda a corrente foi DESLIGADA, localize o disjuntor no painel que serve o circuito de
corrente connua e coloque-o na posição OFF (Desligado), segurando nessa posição a
manivela do interruptor do disjuntor com ta isoladora.
¡Atención! Antes de proceder con los siguientes pasos, comprobar que la alimentación
del circuito de corriente connua (CC) esté cortada (OFF). Para asegurarse de que toda
la alimentación esté cortada (OFF), localizar el interruptor automáco en el panel que
alimenta al circuito de corriente connua, cambiar el interruptor automáco a la
posición de Apagado (OFF), y sujetar con cinta la palanca del interruptor automáco en
posición de Apagado (OFF).
Varning! Innan du uör någon av följande procedurer måste du kontrollera a
strömförsörjningen ll likströmskretsen är bruten. Kontrollera a all strömförsörjning är
BRUTEN genom a slå AV det överspänningsskydd som skyddar likströmskretsen och
tejpa fast överspänningsskyddets omkopplare i FRÅN-läget.
DC Power Grounding Requirements and Warning
An insulated grounding conductor that is idencal in size to the grounded and ungrounded branch
circuit supply conductors but is idenable by green and yellow stripes is installed as part of the branch
circuit that supplies the device. The grounding conductor is a separately derived system at the supply
transformer or motor generator set.
WARNING: When you install the device, the ground connecon must always be made
rst and disconnected last.
Waarschuwing Bij de installae van het toestel moet de aardverbinding aljd het eerste
worden gemaakt en het laatste worden losgemaakt.
390

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4300 Series and is the answer not in the manual?

Juniper EX4300 Series Specifications

General IconGeneral
Product SeriesEX4300 Series
Power ConsumptionVaries by model and configuration
Virtual Chassis TechnologyUp to 10 switches
SoftwareJunos OS
Ports24-port and 48-port models
10GBASE SFP+ PortsUp to 8 ports
40GBASE QSFP+ Ports2
Uplink PortsUp to 4 ports
Jumbo FramesUp to 9216 bytes
Operating Temperature0°C to 45°C
Relative Humidity5% to 90% noncondensing
Input Voltage100 to 240V AC
Power SupplyAC or DC
Power Supply OptionsAC or DC
StackingYes
Layer 2 FeaturesIncludes VLAN, STP, RSTP, MSTP, LACP
Layer 3 FeaturesOSPF, BGP
ManagementCLI, Web GUI, SNMP
Security FeaturesDHCP snooping
QoS8 queues per port, DSCP
Storage Temperature-40°C to 70°C

Related product manuals