Table 54: EX Series Switch Environmental Tolerances
(Connued)
Switch or
device
Environment Tolerance
Altude Relave Humidity Temperature Seismic
EX9214
No performance
degradaon up to
10,000 feet
(3048 meters)
Normal operaon
ensured in the relave
humidity range 5%
through 90%
(noncondensing)
Normal operaon is
ensured in the
temperature range 32° F
(0° C) through 104° F
(40° C)
Nonoperang storage
temperature in shipping
container: – 40° F (–
40° C) through 158° F
(70° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63.
EX9251
The maximum
thermal
output is
1705 BTU/
hour (500 W).
No performance
degradaon up to
10,000
(3048 m)
Normal operaon
ensured in relave
humidity range of 5% to
90%, noncondensing
Normal operaon ensured
in temperature range of
32° F (0° C) to 104° F
(40° C)
Nonoperang storage
temperature in shipping
container: – 40° F (–
40° C) to 158° F (70° C)
Complies with
Telcordia
Technologies
Zone 4
earthquake
requirements
XRE200 No performance
degradaon up to
10,000 feet
(3048 meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon ensured
in the temperature range
41° F (5° C) through
104° F (40° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
NOTE: Install EX Series switches only in restricted areas, such as dedicated equipment rooms
and equipment closets, in accordance with Arcles 110– 16, 110– 17, and 110– 18 of the
Naonal Electrical Code, ANSI/NFPA 70.
130

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4300 Series and is the answer not in the manual?

Juniper EX4300 Series Specifications

General IconGeneral
Product SeriesEX4300 Series
Power ConsumptionVaries by model and configuration
Virtual Chassis TechnologyUp to 10 switches
SoftwareJunos OS
Ports24-port and 48-port models
10GBASE SFP+ PortsUp to 8 ports
40GBASE QSFP+ Ports2
Uplink PortsUp to 4 ports
Jumbo FramesUp to 9216 bytes
Operating Temperature0°C to 45°C
Relative Humidity5% to 90% noncondensing
Input Voltage100 to 240V AC
Power SupplyAC or DC
Power Supply OptionsAC or DC
StackingYes
Layer 2 FeaturesIncludes VLAN, STP, RSTP, MSTP, LACP
Layer 3 FeaturesOSPF, BGP
ManagementCLI, Web GUI, SNMP
Security FeaturesDHCP snooping
QoS8 queues per port, DSCP
Storage Temperature-40°C to 70°C